NoLog
Purpose
This property allows you to get or set whether logging is to take place on the process this property is set from. If you set this property in a script, then all logging entries from procedures run from the script are stopped. If this property is set from a plug-in, then logging from that plug-in is prevented until NoLog is reset or the plug-in is shut-down and restarted.
Parameters
Parameter: NoLog
Type: Boolean
Description: When set to True, logging for the process thread is turned off.
Returns
Return value: NoLog
Type: Boolean
Description: Provides the current NoLog setting for the process the property is retrieved from.
Example
To disable logging for the current process thread (script, plug-in, event):
Sample Code
hs.NoLog = True
Note
Log entries (e.g. WriteLogDetail) which include a Priority value of 1 (highest) are always written regardless of the NoLog setting.